Door Types

Custom-Engineered for Every Clinical Configuration

Whether your facility requires a sliding, hinged or specialty door — every unit is individually designed for your bunker geometry, beam energy, maze configuration and local regulatory requirements.

Sliding LINAC radiation shielding door motorized
Most Popular

Sliding LINAC Doors — Photon & Neutron

Heavy-duty motorized sliding doors for high patient-volume centers. Maximum shielding thickness in a compact footprint. Dual-layer photon and neutron protection for 6–18 MV systems.

  • Lead (photon) + BPE (neutron) multi-layer core
  • PLC-controlled fully automatic operation
  • Rail system rated for heavy shielding loads
  • Radiation-tight sealing on all 4 edges
  • Presence detection & safety interlock system
  • Emergency battery backup power
Request specifications →
Hinged LINAC radiation shielding door swing type
Cost Effective

Hinged LINAC Doors — Photon & Neutron

Robust single or double-leaf hinged doors with proven mechanical reliability. Lower long-term maintenance. Ideal for facilities with adequate maze corridor space.

  • Lead + BPE dual-layer shielding
  • Manual or fully automatic operation
  • Electro-mechanical & hydraulic drive options
  • Left-hand or right-hand swing
  • 6 MV – 15 MV systems
  • Stainless or carbon steel construction
Request specifications →
CT simulator brachytherapy shielding door architectural finish
Specialty

CT-SIM & Brachytherapy Doors

Purpose-built photon shielding doors for CT simulation rooms and HDR brachytherapy suites. Architectural finish options integrate seamlessly with clinical interiors.

  • Wood veneer & laminate finish options
  • Concealed overhead sliding mechanism
  • Lead photon shielding core
  • Access control system integration
  • HDR brachytherapy & CT-SIM compliance
Request specifications →
Radiotherapy bunker shielding design calculations NCRP 151
Engineering Service

Treatment Room Design & Shielding Calculations

NCRP 151 compliant shielding calculations, bunker layouts, maze geometry optimization and complete radiotherapy project design support from concept to commissioning.

  • Primary & secondary barrier calculations
  • Neutron fluence & capture gamma analysis
  • Dose rate evaluations for all occupied areas
  • Maze geometry optimization
  • Regulatory compliance documentation
Explore room design →
LINAC installation relocation project management
Turnkey

Project Management: Installation & Relocation

Full project management for new LINAC installations and equipment relocations. From decommissioning and transport to new door supply, installation and acceptance testing.

  • Specialized rigging & handling teams
  • Minimal clinical downtime planning
  • New shielding door supply & installation
  • Acceptance testing & commissioning
  • International logistics coordination
Explore project management →
Shielding material supply lead BPE borated polyethylene
Materials Supply

Shielding Materials Supply

Complete supply of photon and neutron shielding materials for bunker wall reinforcement and upgrade projects worldwide. Sourced and quality-controlled in-house.

  • Virgin lead plates, blocks & interlocking bricks
  • Borated polyethylene (BPE) panels & blocks
  • Borated paraffin composites
  • High-density concrete additives
  • International shipping available
Explore materials supply →
Lead lined X-ray room shielding door with architectural finish
Imaging

X-Ray Doors

Lead-lined doors for diagnostic and interventional X-ray rooms — radiography, fluoroscopy and cath-lab suites. Kilovoltage shielding calculated per room workload, delivered in clinical architectural finishes.

  • Lead lining per project shielding report
  • Hinged single/double leaf or sliding
  • Optional lead glass observation window
  • Warning light & access control integration
Explore X-Ray doors →
Cyclotron radiation shielding doors — motorized plug door with lead and borated polyethylene shielding for PET radiopharmaceutical vaults
High Neutron Field

Cyclotron Doors

Heavy multi-layer doors for PET radiopharmaceutical cyclotron vaults, where intense neutron fields during operation demand borated hydrogenous shielding combined with photon attenuation layers.

  • Borated polyethylene/paraffin + lead build-up
  • Motorized sliding execution for heavy leaves
  • Interlock integration with cyclotron controls
  • Post-installation neutron & gamma survey
Explore cyclotron doors →
Custom made radiation shielding door for non-standard opening
Special Projects

Custom-Made Doors

Shielding doors engineered for non-standard requirements — oversized openings, research facilities, industrial irradiation rooms and retrofit projects with structural constraints.

  • Per-project shielding & mechanical design
  • Oversized & non-standard geometries
  • Research and industrial applications
  • Retrofit into existing structural openings
Explore custom solutions →
LINAC chiller solutions for high energy and low energy linear accelerator cooling
Equipment

LINAC Chillers

Supply and installation of water chiller systems for linear accelerator cooling — sized to the machine vendor’s site planning requirements, with redundancy options for uninterrupted clinical operation.

  • Sized per LINAC vendor cooling specifications
  • New installations & replacement projects
  • Redundant / backup configuration options
  • Commissioning with the accelerator vendor
Explore LINAC chillers →
Radiation shielding commissioning survey and acceptance documentation
Verification Service

Commissioning

Independent verification that the installed shielding performs as calculated — radiation surveys at the closed door and around the vault, interlock function testing and the acceptance documentation your regulator expects.

  • Photon & neutron dose measurements
  • Door interlock & safety chain testing
  • Survey report for regulatory submission
  • Sign-off against NCRP 151 design limits
Explore commissioning →
Shielding Materials

In-House Material Quality Control

We source, process and quality-control all shielding materials in-house — ensuring every door meets its specified attenuation performance.

Lead shielding bricks photon attenuation LINAC door

Lead — Photon Shielding

Virgin lead conforming to ASTM B-29. Defect-free, uniform thickness (max 3% variation). Used for primary photon attenuation in all LINAC door types across all energy levels.

Borated paraffin polyethylene neutron shielding BPE

Borated Paraffin & BPE — Neutron Shielding

Minimum 5% boric oxide content per IAEA requirements. Hydrogen-rich borated polyethylene and paraffin composites for neutron thermalization and capture in high-energy vaults above 10 MV.

Full photon neutron shielding material supply range

Full Material Supply for Projects

Lead plates, interlocking blocks, borated polyethylene panels and composites for bunker wall reinforcement, maze shielding and door system upgrades worldwide.

Ready to Discuss Your Radiotherapy Project?

Whether you are a hospital, distributor, contractor or oncology clinic — our engineering team is ready to support your photon and neutron shielding project from day one.

Request a Technical Quote →
💬