Photon & Neutron Shielding Specialists

Precision LINAC Doors
with Photon & Neutron
Shielding

MSA Projecta engineers and manufactures custom LINAC doors with dual-layer photon and neutron protection for radiotherapy facilities worldwide. Every door is individually calculated per your bunker geometry, beam energy and NCRP 151 requirements.

20+
Years of
engineering experience
500+
Projects
worldwide
3
Continents
served
6–18 MV
Full energy
range
LINAC sliding shielding door LINAC hinged shielding door
🛡 100% Photon & Neutron Shielding Guaranteed
✅ NCRP 151 · IAEA · ICRP Compliant
⚙ Varian · Elekta · Siemens · Accuray Compatible
🚀 15-Day Production Lead Time

Compatible with all major LINAC manufacturers

Varian Medical Systems Elekta Siemens Healthineers Accuray
Our Core Product

Photon & Neutron
Shielded LINAC Door

🛡 Dual-Layer Radiation Protection

A LINAC door is the most critical radiation safety component in any radiotherapy bunker. When a linear accelerator operates above 10 MV, it generates both photon (X-ray) and secondary neutron radiation — requiring a dual-layer shielding system that addresses both radiation types simultaneously.

Structural steel frame

Carbon steel or stainless steel outer structure providing mechanical strength and radiation-tight edge sealing on all 4 sides.

Lead shielding — photon attenuation

Virgin lead (ASTM B-29) for primary photon (X-ray & gamma) attenuation. 5–50 mm Pb equivalent, project-specific. Uniform thickness, max 3% variation.

Borated polyethylene — neutron capture

Hydrogen-rich borated polyethylene (min. 5% boric oxide, IAEA compliant) for neutron attenuation. 50–100 mm equivalent. Required for LINACs above 10 MV.

100% Shielding Performance Guarantee

Every MSA Projecta door is individually calculated by radiation physicists per NCRP 151 for your specific bunker geometry, beam energy and workload. Shielding integrity verified at installation.

LINAC sliding shielding door — open position LINAC hinged shielding door — front view
Neutron shielded hinged LINAC door — open side view LINAC sliding shielding door — closed position
Neutron shielded LINAC door — sliding and hinged technical specifications and bunker layout
Door Types

Custom-Engineered for Every Clinical Configuration

Sliding, hinged and specialty shielding doors — every unit individually designed for your bunker geometry, beam energy and regulatory requirements.

Sliding LINAC radiation shielding door motorized
Most Popular

Sliding LINAC Doors — Photon & Neutron

Heavy-duty motorized sliding doors for high patient-volume centers. Maximum shielding thickness in a compact footprint. Dual-layer photon and neutron protection for 6–18 MV systems.

  • Lead (photon) + BPE (neutron) multi-layer core
  • PLC-controlled fully automatic operation
  • Rail system rated for heavy shielding loads
  • Radiation-tight sealing on all 4 edges
  • Presence detection & safety interlock system
  • Emergency battery backup power
Request specifications →
Hinged LINAC radiation shielding door swing type
Cost Effective

Hinged LINAC Doors — Photon & Neutron

Robust single or double-leaf hinged doors with proven mechanical reliability. Lower long-term maintenance. Ideal for facilities with adequate maze corridor space.

  • Lead + BPE dual-layer shielding
  • Manual or fully automatic operation
  • Electro-mechanical & hydraulic drive options
  • Left-hand or right-hand swing
  • 6 MV – 15 MV systems
  • Stainless or carbon steel construction
Request specifications →
CT simulator brachytherapy shielding door architectural finish
Specialty

CT-SIM & Brachytherapy Doors

Purpose-built photon shielding doors for CT simulation rooms and HDR brachytherapy suites. Architectural finish options integrate seamlessly with clinical interiors.

  • Wood veneer & laminate finish options
  • Concealed overhead sliding mechanism
  • Lead photon shielding core
  • Access control system integration
  • HDR brachytherapy & CT-SIM compliance
Request specifications →
Radiotherapy bunker shielding design calculations NCRP 151
Engineering Service

Bunker Design & Shielding Calculations

NCRP 151 compliant shielding calculations, bunker layouts, maze geometry optimization and complete radiotherapy project design support from concept to commissioning.

  • Primary & secondary barrier calculations
  • Neutron fluence & capture gamma analysis
  • Dose rate evaluations for all occupied areas
  • Maze geometry optimization
  • Regulatory compliance documentation
Request consultation →
LINAC installation relocation project management
Turnkey

LINAC Installation & Relocation

Full project management for new LINAC installations and equipment relocations. From decommissioning and transport to new door supply, installation and acceptance testing.

  • Specialized rigging & handling teams
  • Minimal clinical downtime planning
  • New shielding door supply & installation
  • Acceptance testing & commissioning
  • International logistics coordination
Discuss your project →
Shielding material supply lead BPE borated polyethylene
Materials Supply

Shielding Material Supply

Complete supply of photon and neutron shielding materials for bunker wall reinforcement and upgrade projects worldwide. Sourced and quality-controlled in-house.

  • Virgin lead plates, blocks & interlocking bricks
  • Borated polyethylene (BPE) panels & blocks
  • Borated paraffin composites
  • High-density concrete additives
  • International shipping available
Request material quote →
View All LINAC Door Types & Services →

Ready to Discuss Your Radiotherapy Project?

Whether you are a hospital, distributor, contractor or oncology clinic — our engineering team is ready to support your photon and neutron shielding project from day one.

Request a Technical Quote →
💬